The IR185VHK is an infrared thermometer with Type K input, combining non-contact infrared measurement up to 1850°C with a jack for a K-type thermocouple probe for contact readings up to 1370°C. With 50:1 optics, laser pointer, alarms and logging, it gives technicians both measurement modes in one handheld tool.

  • Infrared plus Type-K contact input
  • Non-contact up to 1850°C
  • K-type probe included
  • 50:1 distance-to-spot ratio
  • 20-point data logging

Temperature range review

Spot size check

Probe input guidance

Emissivity guidance

Calibration support

Still Confused What to Buy?
Need help deciding? Download resources to know more about the product.

https://tipl.com/wp-content/uploads/2026/03/IR185VHK.pdf

  • Infrared thermometer with a jack to connect a Type K thermocouple probe
  • Non-contact infrared measurement up to 1850°C
  • Contact measurement via K-type probe up to 1370°C
  • Bead-type K probe with miniature plug provided
  • 50:1 distance-to-spot ratio for measurement from a distance
  • Response time under 0.15 s
  • Max, Min, Difference or Average simultaneously displayed
  • High and low audible alarms
  • 20-point data logging with data recall
  • Data hold (7 sec) and data recall (Max, Min, Diff, Avg and Log)
  • Backlit dual-row LCD display
  • Non-contact and contact measurement in one handheld tool
  • Handheld high-temperature spot checks
  • Applications needing both non-contact and contact readings
  • Heating and ventilation diagnostics
  • Electrical motor and panel monitoring
  • Insulated wall and pipe checks
  • Refrigeration system diagnostics
  • Furnace and kiln temperature checks
  • Maintenance and preventive inspection
  • Verification of non-contact readings with a probe
  • General industrial diagnostics
  • Model: IR185VHK
  • Product Type: Portable Infrared Thermometer with Type K Input
  • Temperature Range (IR): -50°C–1850°C
  • IR Spectral Range: 8–14 µm
  • Accuracy (IR): -50°C to -20°C ±7°C (typical); -20°C to 0°C ±4°C; 0°C to 100°C ±2.5°C; 100°C to 200°C ±1% rdg ±1°C; 200°C to 400°C ±1.5% rdg ±1°C; 400°C to 1850°C ±2% rdg ±1°C
  • Resolution: 0.1°C <1000°C, 1°C >1000°C on backlit dual-row LCD display
  • Temperature Range (K type): -50°C–1370°C
  • Accuracy (K type): -50°C to 1000°C ±1% rdg ±1°C; 1000°C to 1370°C ±1.5% ±2°C
  • Type K Temp Resolution: 0.1°C (<1000°C) / 1°C (>1000°C)
  • Response Time: <0.15 s
  • Distance to Spot Ratio (D:S): 50:1 (calculated at 90% energy)
  • Laser Pointer: Class 2, <1mW power
  • Emissivity: Adjustable 0.10–1.00
  • Operating Voltage: 9V
  • Size, Weight: 225 × 150 × 52.5 mm; 245 g
  • Data Logging: 20 points
  • Alarms: High & low audible alarms
  • Accessories: Battery, manual, mini tripod, K-type temperature probe & black box

    Comprehensive Services Using This Product

    From installation to ongoing support, we’re with you every step of the way.

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions About This Product

    It is a handheld thermometer that measures non-contact by infrared and also accepts a Type K thermocouple probe for contact readings. The IR185VHK reads up to 1850°C by infrared and up to 1370°C by probe.
    Infrared gives fast non-contact readings from a distance, while the Type K probe gives direct contact readings, so users can cross-check or measure targets where one method suits better.
    By infrared it covers -50°C to 1850°C; by the K-type probe it covers -50°C to 1370°C.
    Yes. A bead-type K-type probe with a miniature plug is provided with the instrument.
    The IR185VHK offers a 50:1 distance-to-spot ratio, so it can measure smaller targets from further away.
    Yes. It offers 20-point data logging with data hold (7 sec) and recall of Max, Min, Difference, Average and Log.
    Users should check the maximum target temperature, whether contact input is needed, distance, spot size and emissivity.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.