Online Infrared Thermometer IRF Series

IRF Series

The IRF Series is a fiber optic infrared thermometer with a high-temperature-resistant optical sensing head and a separate electronics box. The bendable fiber reaches tight or hot spots, the head resists EMI, and one-colour and two-color types give non-contact readings from 150°C to 3000°C for continuous monitoring.

  • Fiber optic sensing head
  • High ambient resistance
  • Immune to EMI
  • One-colour or two-color types
  • Built-in center laser aiming

Temperature range review

1C / 2C selection

Fiber length guidance

Spot size check

Commissioning support

Still Confused What to Buy?
Need help deciding? Download resources to know more about the product.

https://tipl.com/wp-content/uploads/2026/03/IRF.pdf

  • Fiber optic infrared thermometer with high-temperature-resistant optical sensing head
  • Optical head immune to electromagnetic field interference
  • Bendable optical fibre reaches places other probes cannot
  • Built-in center laser aiming, no external aiming-light accessory needed
  • Available in one-colour and two-color (ratio) types
  • Two-color model resists smoke, water vapour and dust; unaffected by dirty window glass
  • Two-color model can measure smaller targets free from distance-coefficient limits
  • Non-contact, continuous measurement with environmental temperature compensation
  • Optical resolution options of 44:1, 120:1 and 200:1
  • 4–20 mA isolated output, RS485 networked output and alarm relay output
  • Probe ambient up to 200°C standard, optional up to 315°C
  • Especially good for liquid metal and low-emissivity applications (2-colour)
  • High-ambient furnace and metallurgy areas
  • Aerospace and scientific research
  • Iron, steel and industrial furnaces
  • Glass melting and vacuum furnaces
  • Single crystal and polycrystalline furnaces
  • Liquid metal and low-emissivity measurement
  • EMI-prone installation locations
  • Hard-to-reach mounting points needing a bendable fibre
  • Continuous high-temperature process control
  • Quality control in harsh environmental conditions
  • Model: IRF Series
  • Product Type: Fiber Optic Online Infrared Thermometer (1C / 2C)
  • Temperature Range: 150°C–3000°C (see ranges)
  • Accuracy: ±0.75%
  • Repeatability: ±0.2%
  • Resolution: 1°C
  • Output Resolution: 0.1°C
  • Emissivity (1C mode): 0.10–1.30, adjustable in steps of 0.01
  • Slope (2C mode): 0.80–1.20, adjustable in steps of 0.01
  • Measurement Modes: Instantaneous, maximum, average
  • Operation & Display: Three-button operation; 4-digit LED digital display, 5 LED alarms
  • Optical Resolution (D:S): 44:1, 120:1, 200:1
  • Min. Measurable Target: Φ2.5 mm (D:S 120:1) @300 mm; Φ6.8 mm (D:S 44:1) @300 mm
  • Output Signal: 4–20 mA (fully isolated), RS485 (networked, fully isolated), high/low alarm relay output
  • Response Time: 50 ms (customise to 10 ms)
  • Digital Communication: RS485, Modbus RTU
  • Power Supply: DC 18–24V
  • Power Consumption: 100 mA with display operation; 50 mA low power mode
  • Probe Ambient Temperature: 0–200°C; optional up to 315°C
  • Electronics Box Ambient Temperature: 0–70°C
  • Humidity: 10–90% (non-condensing)
  • Storage Temperature: -40°C–85°C
  • Fiber Cable: 2.2 m standard; 6 m, 10 m, 22 m optional
  • Electronic Box: 175 × 80 × 58 mm
  • Weight: Optical head 150 g, electronic box 800 g

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions About This Product

    A fiber optic infrared thermometer uses an optical sensing head joined by a bendable fiber to a separate electronics box. The head resists high ambient heat and EMI, so the IRF can measure 150°C to 3000°C in hard-to-reach or hot locations.
    The optical head resists high ambient temperature and only transmits infrared energy, so it is immune to electromagnetic interference and can be installed where other probes cannot.
    The one-colour (1C) model suits clear viewing, while the two-color (2C) model resists smoke, vapour and dust, ignores dirty window glass, and can measure smaller targets free from distance-coefficient limits.
    The IRF covers 150°C to 3000°C across configurable ranges, depending on the selected wavelength and 1C/2C type.
    The IRF provides a fully isolated 4–20 mA output, networked RS485 Modbus output and a high/low alarm relay output for continuous monitoring.
    Fiber cable is 2.2 m standard, with 6 m, 10 m and 22 m optional.
    Users should check target temperature, 1C/2C type, probe ambient temperature, fiber length, spot size and output requirement.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.