Portable Infrared Thermometer IR65VS & IR105VS

IR65VS / IR105VS

The IR65VS and IR105VS are dual laser infrared thermometers whose twin lasers converge at 156 mm to mark the exact 13 mm measuring spot, and indicate spot size at other distances. Reading up to 650°C and 1050°C respectively, they give technicians accurate non-contact targeting for maintenance and HVAC checks.

  • Dual converging laser targeting.
  • Marks exact measuring spot.
  • Non-contact from a safe distance.
  • High & low audible alarms.
  • 20-point data logging

Temperature range review

Spot size check

Emissivity guidance

Distance guidance

Calibration support

Still Confused What to Buy?
Need help deciding? Download resources to know more about the product.

https://tipl.com/wp-content/uploads/2026/03/IR65VS-IR105VS.pdf

  • Dual laser targeting: twin lasers converge to mark the exact measuring spot.
  • Converge to a single spot at 156 mm to identify a 0.5" (13 mm) spot.
  • Laser spots indicate approximate spot diameter at other distances.
  • Wide range up to 1050°C (IR105VS).
  • 12:1 distance-to-spot ratio.
  • Response time under 1 second
  • Max, Min, Difference or Average simultaneously displayed
  • High and low audible alarms
  • 20-point data logging with data recall
  • Data hold (7 sec) and data recall (Max, Min, Diff, Avg and Log)
  • Adjustable emissivity 0.10–1.00
  • Non-contact measurement for HVAC, electrical and refrigeration diagnostics
  • Handheld spot temperature checks
  • Heating and ventilation diagnostics
  • Electrical motor and panel monitoring
  • Insulated wall and pipe checks
  • Refrigeration system diagnostics
  • Maintenance and preventive inspection
  • Accurate spot targeting on small components
  • Non-contact measurement from a safe distance
  • Electrical equipment temperature surveys
  • General industrial diagnostics
  • Models: IR65VS / IR105VS
  • Product Type: Dual Laser Portable Infrared Thermometer
  • Temperature Range: IR65VS -50°C–650°C; IR105VS -50°C–1050°C
  • IR Spectral Range: 8–14 µm
  • Accuracy: -50°C to -20°C ±7°C; -20°C to 0°C ±4°C; 0°C to 100°C ±2.5°C; 100°C to 200°C ±1% rdg ±1°C; 200°C to 400°C ±1.5% rdg ±1°C; 400°C to 1050°C ±2% rdg ±1°C
  • Resolution: 0.1°C <1000°C, 1°C >1000°C on backlit dual-row LCD display
  • Distance to Spot Ratio (D:S): 12:1 (calculated at 90% energy)
  • Response Time: <1 s
  • Laser Pointer: Dual, Class 2, <1mW power
  • Emissivity: Adjustable 0.10–1.00
  • Operating Voltage: 9V
  • Size, Weight: 173 × 115 × 44 mm; 130 g
  • Data Logging: 20 points
  • Display Functions: Max, Min, Difference, Average; data hold (7 sec) and data recall
  • Alarms: High & low audible alarms
  • Accessories: 9V battery, manual and black pouch

    Comprehensive Services Using This Product

    From installation to ongoing support, we’re with you every step of the way.

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions About This Product

    A dual laser infrared thermometer uses two lasers that converge to mark the exact spot being measured. On the IR65VS and IR105VS, the lasers meet at 156 mm to show a 13 mm spot, improving targeting accuracy.
    The two laser dots converge at the focal distance to mark the exact measured spot, and at other distances they indicate the approximate spot diameter, so users aim precisely and avoid measuring the wrong area.
    Both share the same dual-laser design and 12:1 optics; the IR65VS measures up to 650°C and the IR105VS up to 1050°C.
    Yes. The IR65VS and IR105VS measure temperature without contact, so technicians can check targets from a safe distance.
    Yes. They offer 20-point data logging with data hold (7 sec) and recall of Max, Min, Difference, Average and Log.
    They provide high and low audible alarms, and can display Max, Min, Difference or Average simultaneously.
    Users should check the maximum target temperature, distance, spot size, emissivity and data-logging needs.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.