Two Color Portable Infrared Thermometer IRP 1R / 2R Series

IRP 1R / 2R Series

The IRP 1R/2R is a two color portable pyrometer that measures temperature from the ratio of energy at two wavelengths. This keeps readings accurate through smoke, steam, dust and dirty windows, and on small or partly obscured targets, giving non-contact measurement up to 3000°C with a high 250:1 D:S ratio.

  • Two-color ratio measurement
  • Reads through smoke, steam, dust
  • Non-contact up to 3000°C
  • High 250:1 D:S ratio
  • Emissivity-change tolerant

Temperature range review

Wavelength selection

Spot size check

Sighting guidance

Calibration support

Still Confused What to Buy?
Need help deciding? Download resources to know more about the product.

https://tipl.com/wp-content/uploads/2026/03/Two-color-IRP-Portable.pdf

  • Two color / ratio infrared temperature measurement technique
  • No influence from window glass, surface finish, emissivity change, smoke, steam or dust
  • Visual, focusable optical aiming viewfinder with target area shown by a circle
  • High D:S ratio of 250:1 for accurate measurement of small targets
  • Through-the-lens sighting to see the exact hot target being measured
  • Focusable optics maintain the D:S ratio across the measuring distance
  • 1000-reading data storage with USB download
  • Display with backlight, enabling use at night
  • 5 measurement modes (Real, Max, Avg, Min & Diff)
  • Non-contact measurement up to 3000°C
  • Single color mode also available on the same instrument
  • Six-key operation with LCD display
  • High-temperature measurement through smoke, steam or dust
  • Small or partly obscured hot target measurement
  • Targets with changing emissivity or surface finish
  • Aerospace and scientific research
  • Iron and steel metallurgy
  • Casting and forging
  • Industrial, vacuum and single crystal furnaces
  • Polycrystalline furnace inspection
  • Non-contact measurement where windows get dirty
  • Verifying other online instruments
  • Model: IRP 1R / 2R Series (two color)
  • Product Type: Two Color (Ratio) Portable Infrared Pyrometer
  • Variants: IRP1RVFDUOM/EUOH, IRP2RVFDUOM/BUOH
  • Temperature Range: 1R 600°C–1800°C / 1000°C–3000°C; 2R 400°C–1200°C (variant dependent)
  • Accuracy: Below 1000°C ±6°C; 1000–1500°C ±0.6% Tm; 1500–2000°C ±1.2% Tm; above 2000°C ±2.4% Tm (Tm = measured value)
  • Repeatability: ±1°C
  • Response Time: 0.1 s
  • Display Resolution: 1°C
  • Wavelengths: 1R 0.96 µm / 1.06 µm; 2R 1.36 µm / 1.60 µm
  • Slope (Emissivity Ratio): 0.80 to 1.30 (two-color mode); Emissivity 0.10 to 1.30 (single-color mode)
  • Measurement Mode: Real-time, maximum, average, difference
  • Operation & Display: Six-key operation, trigger; LCD digital display
  • Storage: 1000 data (temperature with calendar/clock)
  • Status: Measure/hold state, high/low alarm with buzzer, battery status
  • D:S (Optical Resolution): 120:1 / 250:1 (variant dependent)
  • Measuring Distance: 0.6 m to ∞
  • Minimum Target Size: Φ2.4 mm to Φ5 mm (variant dependent)
  • Sighting: Visual (through-the-lens) sighting
  • Power Supply: 2 AA alkaline batteries
  • Power: 20 mA (max), min 50 hours continuous operation
  • Storage Temperature: (-)40–85°C
  • Ambient Temperature: 0–60°C
  • Relative Humidity: 0–80% non-condensing
  • Instrument Size: 200 × 173 × 55 mm
  • Weight: ≤510 g

    Comprehensive Services Using This Product

    From installation to ongoing support, we’re with you every step of the way.

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions About This Product

    A two color portable pyrometer, or ratio pyrometer, measures temperature from the ratio of energy at two close wavelengths. The IRP 1R/2R stays accurate through smoke, steam and dust and on small targets, up to 3000°C.
    Any obstruction usually reduces energy in both wavelengths equally, so the ratio stays the same and the reading remains correct. This lets the IRP 1R/2R measure through smoke, steam, dust and dirty windows, and on partly obscured targets.
    Depending on the variant, the 1R covers 600°C–1800°C or 1000°C–3000°C, and the 2R covers 400°C–1200°C.
    It offers a high D:S ratio up to 250:1, so small targets can be measured accurately at a distance.
    Yes. The instrument supports a single-color mode with emissivity 0.10 to 1.30, in addition to the two-color ratio mode.
    It uses through-the-lens sighting, so the operator looks through an eyepiece and sees the exact hot target the detector is measuring.
    Users should check target temperature, wavelength pair (1R or 2R), spot size at distance, viewing condition and whether single-color mode is needed.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.