TMF-T Electromagnetic Flow Meter

TMF-T

TMF-T electromagnetic flow meter measures conductive liquid flow in inline pipeline applications. It works on Faraday’s law of electromagnetic induction and suits water, wastewater, chemicals, slurry, pulp and other conductive process liquids. Also, it supports integrated diagnostics, empty pipe detection, forward and reverse flow measurement, IP68 protection, HART / Modbus communication, multiple liner and electrode materials, and wide DN3 to DN3000 size selection. As a result, it fits industrial process lines where stable magnetic flow measurement and material compatibility matter.

  • Inline conductive liquid flow
  • DN3 to DN3000 range
  • IP68 protection
  • HART / Modbus options
  • Liner and electrode choices

Conductivity check

Liner selection help

Electrode material guidance

Flow range review

Installation support

Still Confused What to Buy?
Need help deciding? Download resources to know more about the product.

https://tipl.com/wp-content/uploads/2026/03/TMF-T-Electromagnetic-flow-meter.docx_removed.pdf

  • Inline electromagnetic flow meter for conductive liquids
  • Works on Faraday’s law of electromagnetic induction
  • Measures conductive liquid volume flow
  • Suitable for water, wastewater, chemicals, slurry, pulp and other conductive liquids
  • Measures forward and reverse direction flow
  • Integrated verification and diagnostic function
  • Empty pipe detection support
  • Built-in reference electrodes reduce need for ground rings in many applications
  • Dual-frequency excitation with stable zero point
  • Precision coil winding supports uniform magnetic field
  • No moving parts and no pressure loss
  • High protection grade IP68
  • Standard accuracy ±0.5%, optional ±0.25%
  • DN3 to DN3000 mm size selection
  • Conductivity requirement greater than 20 μS/cm for normal liquids
  • Electrode options: SS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum
  • Communication: RS485 / Modbus / HART
  • Signal output: 4-20 mA and pulse
  • Multiple flange standard options including EN, ANSI, JIS, AS and ASME-related standards
  • Water and wastewater flow measurement
  • Effluent treatment plant flow monitoring
  • Raw water and treated water pipelines
  • Cooling water and utility water lines
  • Chemical and pharmaceutical process liquids
  • Slurry and pulp flow measurement
  • Mining and cement slurry applications
  • Food and beverage conductive liquids
  • Steel plant process liquid monitoring
  • Power plant utility and chilled water lines
  • Bidirectional conductive liquid flow applications
  • Corrosive liquid flow measurement with suitable liner and electrode selection
  • Model: TMF-T
  • Product Type: Inline Electromagnetic Flow Meter
  • Measurement Principle: Faraday’s law of electromagnetic induction
  • Measured Media: Conductive liquids
  • Size Range: DN3 to DN3000 mm, 1/8 inch to 120 inch
  • Accuracy: ±0.5% standard, ±0.25% optional
  • Conductivity Requirement: Normal liquid >20 μS/cm
  • Protection Grade: IP68
  • Electrode Material: SS316L standard, Hastelloy C, Hastelloy B, Titanium, Tantalum, Platinum
  • Liner Material: PTFE, PFA, FEP, Neoprene, Polyurethane
  • Power Supply: 220VAC-50Hz, 24VDC
  • Power Consumption: <20W
  • Communication: RS485 / Modbus / HART
  • Ambient Temperature: -20°C to +60°C
  • Relative Humidity: 5% to 95%
  • Velocity Range: 0.1 m/s to 15 m/s
  • Nominal Pressure: 4.0 MPa for DN3–DN150; 1.6 MPa for DN200–DN600; 1.0 MPa for DN700–DN1000; 0.6 MPa for DN1200–DN3000
  • Frequency Output: 1 to 5000 Hz
  • Signal Output: 4-20 mA, pulse
  • Flange Standard: EN1092-1 PN10 / PN16 / PN25 / PN40, ANSI Class 150 / 300 / 600, JIS2220 10K / 20K / 40, AS2129 Table D / Table E, AS4087 PN16 / PN21 / PN35
  • Measuring Tube Material: Stainless Steel 304
  • Flange Material: Carbon Steel standard, Stainless Steel 304 optional, Stainless Steel 316 optional
  • Straight Pipe Requirement: Inlet ≥10D, outlet ≥5D
  • Structure Type: Integral / Remote
  • Flange Type: DIN, ANSI#150, ANSI#300 up to DN50
  • Main Applications: Water, wastewater, chemicals, slurry, pulp, food, mining, cement, steel and power utilities

    What Customers Say About Us

    Accurate Flow Monitoring & Smooth Support

    We recently used the TMF-T Electromagnetic Flow Meter for conductive liquid flow measurement, and the performance has been reliable during plant operation. The readings remained stable, and the delivery, packaging, and support coordination were handled professionally.

    Ms. Soniya Parashar
    Ms. Soniya ParasharSr. Engineer - Quality
    Reliable Solution for Utility Applications

    The Electromagnetic Flow Meter has been very useful for our water and utility flow monitoring requirements. The product quality, documentation support, and overall coordination from order to delivery were managed smoothly.

    Ms. Taral Vaidya
    Ms. Taral VaidyaD.G.M - Wastewater Treatment Plant
    Practical Design for Continuous Operations

    We are satisfied with the overall performance of this electromagnetic flow meter in our plant application. The product design is practical for continuous use, and the packaging, delivery, and technical support experience were very good.

    Ms. Kavita Rao
    Ms. Kavita RaoPlant Head - Water Treatment Plant
    Helpful Features for Daily Process Monitoring

    The TMF-T Flow Meter has supported our daily process monitoring activities effectively during operations. The diagnostic functions and installation support from the technical team were useful for our maintenance and operations staff.

    Mr. S. K. Iyer
    Mr. S. K. IyerDeputy Manager – Operations
    Good Product Quality & Service Experience

    Our experience with the TMF-T Electromagnetic Flow Meter has been positive throughout the process. The product performance, communication options, and after-sales support have matched our operational expectations well.

    Mr. S.K. Roy
    Mr. S.K. RoyProduction Manager

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions

    TMF-T electromagnetic flow meter measures conductive liquid flow in inline pipeline applications. It suits water, wastewater, chemicals, slurry, pulp and other suitable conductive process liquids.
    TMF-T supports DN3 to DN3000 mm, or 1/8 inch to 120 inch, depending on selection.
    For normal liquids, conductivity should be greater than 20 μS/cm.
    TMF-T provides ±0.5% standard accuracy and ±0.25% optional accuracy, depending on selection and application conditions.
    Yes. TMF-T supports RS485 / Modbus / HART communication, depending on configuration.
    Liner options include PTFE, PFA, FEP, Neoprene and Polyurethane.
    Electrode options include SS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum and Platinum.
    No. Electromagnetic flow meters need conductive liquids. Users should not select TMF-T for pure oil, gas, steam or other non-conductive media.
    Users should check liquid conductivity, pipe size, flow range, pressure, temperature, liner material, electrode material, flange standard, grounding, straight-run availability and output requirement.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.