Insertion Type Electromagnetic Flow Meter TMF/C Series

TMF/C Series

TMF/C Series insertion electromagnetic flow meter measures conductive liquid flow in large industrial pipelines. It supports installation under pressure and can help avoid shutdown or pipe cutting in suitable applications. Also, it measures forward and reverse flow, includes empty pipe detection, offers IP65 / IP68 protection and provides 4-20 mA, frequency and communication output options. As a result, it suits large water, wastewater, utility and process liquid lines where full-bore magnetic flow meter installation may be difficult or costly.

  • Large pipe measurement
  • Hot-tap installation support
  • Forward / reverse flow
  • IP65 / IP68 protection
  • No moving parts

Pipe size review

Conductivity check

Installation guidance

Output selection help

Commissioning support

Still Confused What to Buy?
Need help deciding? Download resources to know more about the product.

https://tipl.com/wp-content/uploads/2026/03/TMF-C-Insertion-type-Electro-magnetic-flowmeter.docx.pdf

  • Insertion type electromagnetic flow meter
  • Designed for conductive liquid flow measurement
  • Suitable for large pipeline applications
  • Can be installed without shutdown or pipe cutting in suitable hot-tap applications
  • Measures forward and reverse direction flow
  • Integrated verification and diagnostic function
  • Empty pipe detection support
  • Dual-frequency excitation with stable zero point
  • Precision coil winding for uniform magnetic field
  • No moving parts and no pressure loss
  • Accuracy: ±1.5% of reading
  • Size range: DN100 to DN3000
  • Conductivity requirement above 20 μS/cm
  • IP65 and IP68 protection options
  • Electrode options: SS316L, Hastelloy C, Hastelloy B
  • Body material: SS304 standard, SS316 optional
  • Thread ball valve and flange ball valve connection options
  • 4-20 mA current output and 0-5 kHz frequency output
  • RS485 / Modbus, HART and other communication options as per selection
  • Suitable for water, wastewater and large conductive liquid pipelines
  • Large conductive liquid pipelines
  • Raw water and treated water flow measurement
  • Wastewater and effluent flow monitoring
  • Cooling water and utility water lines
  • Large pipe flow measurement
  • Industrial water distribution
  • Municipal and plant water systems
  • Conductive process liquid monitoring
  • Bidirectional flow measurement
  • Applications where full-bore meter installation is difficult
  • Hot-tap installation applications, subject to site feasibility
  • Existing pipeline flow monitoring
  • Model: TMF/C Series
  • Product Type: Insertion Type Electromagnetic Flow Meter
  • Measurement Principle: Electromagnetic induction
  • Measured Media: Conductive liquids
  • Size Range: DN100 to DN3000 mm
  • Conductivity Requirement: >20 μS/cm
  • Accuracy: ±1.5% of reading
  • Velocity Range: 1 m/s to 10 m/s
  • Working Pressure: ≤1.6 MPa
  • Medium Temperature: Max. 80°C
  • Protection Grade: IP65 / IP68
  • Electrode Material: SS316L, Hastelloy C, Hastelloy B
  • Body Material: SS304 standard, SS316 optional
  • Sensor Probe Material: ABS / Polypropylene
  • Power Supply: AC85–250V, DC20–36V; selection includes 220VAC, 24VDC and battery power options
  • Power Consumption: <15W
  • Display: LCD display, 128 × 128 mm, three lines, 4 internal push buttons
  • Communication: RS485 / Modbus, HART, Profibus / fieldbus option as per selection
  • Signal Output: 4-20 mA current, 0-5 kHz frequency
  • Maximum Sensor / Transmitter Distance: 200 m
  • Ambient Temperature: -25°C to +60°C
  • Relative Humidity: 5% to 90%
  • Flange Standard: DN50, PN16
  • Connection: Thread ball valve, flange ball valve
  • Straight Pipe Requirement: Inlet ≥10D, outlet ≥5D
  • Grounding Resistance: <10Ω
  • Cable Entry: M20 × 1.5
  • Converter Figure: Square / Circular
  • Optional Feature: GPRS, as per selection

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions

    TMF/C Series is used for insertion type electromagnetic flow measurement in large conductive liquid pipelines such as water, wastewater, utility water and suitable process liquid lines.
    TMF/C Series supports DN100 to DN3000 mm pipeline sizes.
    It can support hot-tap or under-pressure installation in suitable applications. However, users must confirm site feasibility, safety practice and process condition before installation.
    The liquid conductivity should be greater than 20 μS/cm.
    Yes. TMF/C can measure forward and reverse direction flow.
    The meter supports 4-20 mA current output, 0-5 kHz frequency output and communication options such as RS485 / Modbus and HART, depending on selection.
    Users should check pipe size, liquid conductivity, flow velocity, working pressure, installation method, straight-run availability, electrode material, output requirement and grounding condition.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.