Submersible Pressure Level Transmitter

TP2041 Series

The TP2041 Series Submersible Pressure Level Transmitter is designed for accurate and reliable liquid level measurement in tanks, reservoirs, bore wells, and open water systems. The transmitter uses a high-performance diffused silicon pressure sensor to measure hydrostatic pressure generated by the liquid column. The measured pressure is converted into a standard 4–20 mA signal, enabling continuous level monitoring in industrial and municipal applications. With stainless steel construction, a special ventilation cable, and surge protection, the TP2041 series ensures stable operation even in demanding environments.

  • Reliable and accurate hydrostatic liquid level measurement
  • Robust stainless steel construction for long-term durability
  • High measurement accuracy with excellent stability
  • Suitable for deep tanks and wells with long cable lengths
  • Built-in surge protection for enhanced safety

Application-Based Customization

Engineered for Your Process Conditions

Expert Selection Support

Reliable After-Sales Service

Still Confused What to Buy?

Need help deciding? Download resources to know more about the product.

https://tipl.com/wp-content/uploads/2026/03/SUBMERSIBLE-PRESSURE-LEVEL-TRANSMITTER-TP2041-Series-1.pdf

  • High-performance diffused silicon pressure sensing technology
  • Multiple measurement range options
  • Real-time liquid level display (with display version)
  • Easy zero and full-scale calibration
  • Special ventilation cable for accurate pressure compensation
  • High precision and long-term stability
  • Inbuilt surge protection
  • Optional LCD display for local level indication
  • SS316L wetted parts for corrosion resistance
  • Suitable for continuous liquid level monitoring
  • Water tanks and reservoirs
  • Bore wells and groundwater monitoring
  • Sewage and wastewater treatment plants
  • Chemical storage tanks
  • Industrial liquid storage tanks
  • Hydrological and environmental monitoring systems
  • Measurement Principle: Hydrostatic Pressure Measurement
  • Measurement Range: 0 mmH₂O to 200 mH₂O
  • Output Signal: 4–20 mA (2-wire), Optional HART
  • Power Supply: 12 – 30 V DC
  • Overload Capacity: 2× FS (5× FS when < 5 mH₂O)
  • Sensor Material: SS316L
  • Housing Material: Stainless Steel
  • Sealing Material: Viton
  • Cable Type: Special Ventilation Cable
  • Accuracy: ±0.1% FS (Min), ±0.25% FS (Typical), ±0.5% FS (Max)
  • Long-Term Stability: ±0.3% FS / year
  • Compensation Temperature: −10°C to +80°C
  • Medium Temperature: −30°C to +85°C
  • Storage Temperature: −40°C to +125°C
  • Protection: Inbuilt Surge Protection

    Comprehensive Services Using This Product

    From installation to ongoing support, we’re with you every step of the way.

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions About This Product

    The transmitter measures hydrostatic pressure generated by the liquid column and converts it into a standard 4–20 mA output signal, which represents the liquid level.
    The transmitter can measure liquids that are compatible with SS316L and Viton sealing materials, such as water, wastewater, and many industrial liquids.
    The TP2041 series supports level measurement up to 200 meters of water column (mH₂O) depending on the selected model.
    Yes, selected models support 4–20 mA output with HART communication for advanced monitoring and configuration.
    Yes. The transmitter supports long cable lengths (up to 200 meters or more), making it suitable for deep wells and large reservoirs.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.