CO2 Fire Extinguisher

KFCRQ-9

CO2 fire extinguisher is a high-pressure trolley-mounted extinguisher for suitable Class B, Class C and electrically started fire risks as per the datasheet application. It uses carbon dioxide gas with 99.5% purity and has a nominal 9 kg charge. Also, it includes a seamless manganese steel body, brass wheel-type valve, aluminium siphon tube, wire braided hose and non-conductor polyethylene discharge horn. As a result, it supports clean fire response in suitable electrical rooms, control rooms, server rooms and industrial equipment areas.

  • Clean CO2 discharge
  • Electrical area support
  • 9 kg trolley type
  • High-pressure design
  • Non-conductor horn

Fire class review

Electrical risk guidance

Placement support

Maintenance planning help

Refilling support

Still Confused What to Buy?
Need help deciding? Download resources to know more about the product.
  • CO2 high-pressure trolley-mounted extinguisher
  • Suitable for Class B, C and electrically started fires as per datasheet
  • 9 kg nominal carbon dioxide charge
  • CO2 gas purity 99.5% as per IS 15222
  • Seamless manganese steel body
  • Brass wheel-type discharge valve
  • Aluminium siphon tube
  • Wire braided discharge hose
  • Electrical non-conductor polyethylene discharge horn
  • MS powder-coated trolley
  • Solid rubber trolley wheel
  • Enamel spray-painted finish
  • BIS and PESO approval support as per datasheet
  • Suitable for electrical panels, control rooms and equipment areas where CO2 use is appropriate
  • Electrical room fire safety
  • Control room fire safety
  • Server room fire response
  • Panel room and equipment area protection
  • Industrial electrical equipment areas
  • Class B and Class C fire-risk areas where CO2 is suitable
  • Factory and plant fire safety points
  • Clean discharge fire response applications
  • Utility and instrumentation rooms
  • Commercial electrical equipment zones
  • Product Type: CO2 High Pressure Trolley Mounted Fire Extinguisher
  • Model Number: KFCRQ-9
  • Type: Trolley Mounted High Pressure
  • Nominal Charge: 9 kg carbon dioxide
  • Extinguishing Medium: CO2 gas, purity 99.5% as per IS 15222
  • Applicable Fire Class: B, C and electrically started fires
  • Fire Rating: 55B
  • BIS Standard Code: IS 16018:2012
  • Body Material: Seamless manganese steel
  • Valve: Brass wheel type as per IS 3224
  • Siphon Tube: Aluminium
  • Discharge Hose: Wire braided hose
  • Discharge Horn: Electrical non-conductor polyethylene horn
  • Trolley: MS powder coated
  • Trolley Wheel: MS plate with solid rubber
  • Temperature Range: -30°C to +60°C
  • Service Pressure: 60–70 bar
  • Test Pressure: 250 bar
  • Hydro Pressure Test: 250 bar / 25 MPa
  • Leakage Test: Dipping into water for leakage check
  • Diameter: 140 ± 10 mm
  • Height: Approx. 1250 mm
  • Full Weight: Approx. 34 kg or 36 kg
  • Finish: PO red as per IS 5, shade 538
  • Accessories: Wall mounting bracket with screw
  • Packing: Corrugated paper and suitable jute bags

    Comprehensive Services Using This Product

    From installation to ongoing support, we’re with you every step of the way.

    What Customers Say About Us

    Trusted Engineering Support

    The team provided clear technical guidance and practical solutions. Execution was smooth and well coordinated throughout.

    Mr. Vivek NairGeneral Manager – Operations, Cement Industry
    Dependable Technical Partner

    Their approach was systematic and aligned with our plant needs. Overall experience with product and service has been positive.

    Ms. Kavita RaoSenior Manager – Maintenance, Steel Sector
    Application-Focused Solutions

    They understood our process conditions before recommending equipment. Support during installation was handled professionally.

    Mr. Rohan MehtaProject Lead – Power Plant
    Consistent Service Delivery

    Product performance has been stable in regular operations. The support team responds in a timely manner.

    Mr. Anil DeshmukhInstrumentation Head, Process Manufacturing

    Insights & News

    Ensuring Environmental Compliance with CEMS: A Step Ahead
    Learn how Continuous Emission Monitoring Systems (CEMS) help industries stay compliant with environmental norms, providing real-time emission data, remote monitoring, and actionable insights for sustainable and responsible manufacturing.
    How Predictive Maintenance is Transforming Industrial Efficiency
    Discover how advanced monitoring tools like vibration and ultrasound solutions are helping industries move from reactive to predictive maintenance—reducing downtime, extending equipment life, and optimizing productivity across critical operations.

    Clients Who Have Transformed Their Operations with This Product

    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo
    Logo

    Frequently Asked Questions

    A CO2 fire extinguisher is used for suitable Class B, Class C and electrically started fire risks as per datasheet application. It is often selected for electrical and clean-discharge areas.
    CO2 is non-conductive and leaves no powder residue. Therefore, it is commonly used where clean discharge is important, subject to site safety procedure and suitability.
    This model has a 9 kg nominal carbon dioxide charge.
    Yes. This CO2 extinguisher is trolley mounted and designed for high-pressure operation.
    It can be used in suitable electrical rooms, control rooms, server rooms, panel rooms and industrial equipment areas where CO2 type protection is appropriate.
    Users should check fire class, room size, ventilation, operator safety, equipment risk, placement, maintenance and refilling requirement before selection.

    Download Resources

    Send Us Your Requirements

    We will respond you soon.

    Share:
    Send Us Your Requirements

    Fill the form to download resources

    Send Us Your Requirements

    We will respond you soon.