PRECISION UNIVERSAL CALIBRATOR IT 52.54

  • Process Meter is a hand held, battery operated tool for measuring electrical parameters. It has all the features of a digital multimeter (besides the feature of RTD and Thermocouple), it could also output signals of direct voltage, current, resistance, temperature and frequency as well
  • Auto/manual range switch,measure value display hold
  • The thermocouple high accuracy cold-end can autooffset
  • Panel auto calibrated
  • The function of auto closed backlight and auto power off
  • Large LCD include white LED backlight
  • It is easy to operation by user, cabinet and solid adapt to be used at locale

Measuring
Function

Range

Measuring
range

Resolving
Power

Accuracy

Remark

DC Voltage

+4V

-4.000V~
4.000V

1mV

0.2%+4

Input impedance:
10MΩ

40V

-40.00V~
40.00V

0.01V

0.2%+4

400V

-400.0V~
400.0V

0.1V

0.2%+4

AC
Voltage(40Hz~
500
Hz) (5%~
100%RANG)

400mV

0~
400.0mV

0.1mV

1%+4

Input impedance :
10MΩ

4V

0~
4.000V

1mV

0.5%+4

40V

0~
40.00V

0.01V

0.5%+4

400V

0~
400.0V

0.1V

0.5%+4

DC mV
Voltage

40mV

-40.00mV~
40.00mV

0.01mV

0.5%+6

Input impedance:
10MΩ

400mV

-400.0mV~
400.0mV

0.1mV

0.2%+4

OHM

400OΩ

0~
400.0OΩ

0.1OΩ

0.2%+4Ω

Plough voltage:
0.4V
Not including
the accuracy of
down-lead
resistance

4kΩ

0~
4.000kΩ

0.2%+4

40kΩ

0~
40.00kΩ

0.01kΩ

0.2%+4

400kΩ

0~
400.0kΩ

0.1kΩ

0.2%+4

4MΩ

0~
4.000MΩ

1kΩ

0.2%+4

40MΩ

0~
40.00MΩ

0.01MΩ

1%+4

DC Current

40mA

0-40.00mA~
40.00mA

0.01mA

0.2%+4

Input impedance:

400mA

400.00mA~
400.00mA

0.1mA

0.2%+4

AC Current
(40Hz~200Hz)
(5%~100%)

40mA

0~
40.00mA

0.01mA

0.5%+4

Input impedance:

400mA

0~
400.00mA

0.1mA

0.5%+4

Frequency

50Hz

0~
50.0 Hz

0.01Hz

0.1%+3

 

500Hz

0~
500.0 Hz

0.1Hz

0.1%+3

5kHz

0~
5.000 kHz

1Hz

0.1%+3

50kHz

0~
50.00k Hz

0.01kHz

0.1%+3

100kHz

0~
100.0k Hz

0.1kHz

0.1%+3

Duty cycle

0.1%~9
9%

 

0.1%

1%

 

Diode test

1V

 

0.001V

10%

Plough voltage
1.1V~1.6V
Current of
short circuit :
0.6mA

Continuity
test

=50OBB

 

0.1Ω

 

Thermocouple

R

-40°C~
1760°C

1°C

0.5%+3(=100°C)
0.5%+2( >100°C)

Adopt Its
-90thermometric
scale not
including the
accuracy of RJC
error RJC
error:±20

S

-20°C~
1760°C

K

-200°C~
950°C

1°C

0.2%+2(=100°C)
0.5%+1( >100°C)

E

-200°C~500°C

J

-200°C~700°C

T

-200°C~400°C

N

-200°C~
1000°C

1°C

0.5%+3(400~
600°C0.5%
+2(
>600°C)

B

400°C~
1800°C

Thermo
resistance

Pt100

-200°C~
700°C

1°C

0.5%+2

Pt100-385
thermometric
scale, not including
the
accuracy of down-lead resistance

Cu50

-50°C~
150°C

1°C

0.5%+4

Output Function

Function

Range

Setting
range

Resolving
power

Accuracy

Remark

OMH

400Ω

0~
400.0Ω

0.1Ω

0.2%+4

±1mA current
not including
the accuracy of
down-lead resistance

79 DC mV

100mV

-10.00mV~
110.00mV

0.01mV

0.2%+4

Max. output current:
5mA

DCV

5V

-0.5000V~
5.5000V

1mV

0.2%+4

Max. output current:
5mA

FREQ

100Hz

1.0Hz~
110.0Hz

0.1Hz

0.2%+2

50% duty cycle
5VP-P

1kHz

0.100kHz~
1.100kHz

0.001kHz

0.2%+2

10kHz

1.0kHz~
11.0kHz

0.1kHz

0.2%+2

Analog transducer
XMT

-20mA

0~
-22.000mA

0.01mA

0.2%+4

Outside power
supply 28V
when 20mA
1kΩ
resistance

DC mA

20mA

0~
22.000mA

0.01mA

0.2%+4

Outside power
supply 15V
when 20mA
400Ω
resistance

Thermocouple

R

-40°C~
1760°C

1°C

0.2%+3
(=100°C)
0.5%+2
( >100°C)

Adopt Its-
90thermometric
scale not including
the accuracy of RJC
error RJC error:±2°C

S

-20°C~
1760°C

0.1°C

K

-200°C~
1370°C

0.5%+20 (=-100°C)
0.5%+10
( >-100° )

E

-200°C~
1000°C

J

-200°C~
1200°C

T

-200°C~
400°C

N

-200°C~
1300°C

B

400°C~
1800°C

1°C

0.5%+3 (400~600°C)
0.5%+2
( >600°C)

Thermo
resistance

Pt100

200°C~
850°C

0.1°C

0.2%+6

Pt100-385
thermometric scale
±0.1mA not
including the
accuracy of
down-lead resistance

Cu50

-50°C~
150°C

 

All technicians responsible for installing, commissioning, calibrating and maintaining process industry transmitters including Instrument and Electric Shop Technicians, Instrument and Control Shop Technicians, Maintenance Technicians.