The new fluke TiR1 and TiR Thermal Imagers are perfect imagers for building envelopes, restoration and remediation, inspection and roofing applications. All Fluke imagers comes with IR Fusion Technology. IR Fusion Technology See things both ways-- Infrared and visual (visible light) images fused together communicating critical information faster and easier. IR -Fusion technology simultaneously captures a digital photo n addition to the infrared image and fuses together taking the mystery out of IR image anaysis. IR -Fusion is standard on Fluke TiR1 and TiR models.
- All Fluke imagers comes with IR -Fusion Technology.
- Rugged and reliable: Engineered to withstand a 2m (6.5 ft) drop.
- 9.1 cm (3.6 in) diagonal landscape color VGA (640 × 480) LCD.
- Temperature range and thermal sensitivity optimized for building diagnostics applications.
- Perfect for any application and budget.
- Excellent thermal sensitivity for seeing even small temperature difference (which could indicate problems)
- Adjustable hand strap for left – or right – handed users.
Detailed Specifications
| Temperature |
| Temperature measurement range
(not calibrated below -10 ºC) |
-20ºC to +100ºC (-4ºF to +212ºF) |
| Accuracy |
± 2 ºC or 2 % (whichever is greater) |
± 5 ºC or 5 % (whichever is greater) |
| Measurement modes |
Smooth Auto Scaling & Manual Scaling |
| On Screen emissivity correction |
Yes |
-- |
| Imaging Performance |
| Field Of View |
23º x 17º |
|
| Spatial Resolution |
2.5 mRad |
|
| Minimum Focus distance |
Thermal Lens: 15 cm (6 in); Visible (visual) light lens: 46 cm (18 in) |
| Focus |
Manual |
| Image Frequency |
9 Hz refresh rate |
| Detector type |
160 x 120 focal plane array, uncooled microbolometer |
| Infrared Lens Type |
20 mm F = 0.8 lens |
| Thermal Sensitivity (NETD) |
≤ 0.07º C at 30º C(70 mK) |
≤ 0.1º C at 30º C(100 mK) |
| Infrared spectral Band |
7.5 μm to 14 μm |
| Visual Camera |
640 x 480 resolution |
| Image Presentation |
| Palettes |
Ironbow, blue-red, high contrast, amber, hot metal, grey |
Ironbow, blue-red, high contrast, amber, hot metal, grey |
| Level and span |
Smooth auto scaling and manual scaling of level and span |
| Minimum Span (in manual mode) |
2.5 ºC (4.5 ºF) |
| Minimum Span (in auto mode) |
5 ºC (9 ºF) |
| IR-Fusion Information |
Full Infrared with MAX, MID, or MIN automayic blending; and picture in picture with MAX,MID,or MIN automatic blending Visual and IR blending |
Full Infrared or Picture -in- Picture |
| Picture -in- Picture (PIP) |
Three level on screen IR blending displayed in center 320 × 240 pixels |
100% IR displayed in center 320 × 240 pixels |
| Full Screen (PIP off) |
Three level on screen IR blending displayed in center 640 × 480 pixels |
100% IR displayed in center 640 × 480 LCD |
| Voice Annotation |
| Voice Annotation |
60 seconds maximum recording time per image |
-- |
| Image and Data Storage |
| Storage Medium |
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotation or 3000 basic (.bmp) IR images |
| File Formats |
SD memory card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotation or 3000 basic (.bmp) IR images |
|
JPEG, BMP, GIF, PNG, TIFF, WMF, EXIF, and EMF
|
General Specifications
| Temperature |
Operating: - 10 ºC to 50 ºC (14 ºF to 122 ºF) storage: - 20 ºC to +50ºC (-4 ºF to 122ºF) without batteries |
| Relative Humidity |
10% to 90% non condensing |
| Display |
9.1 cm (3.6 in) diagonal landscape colour VGA (640×480) LCD with backlight() |
| Control and adjustments |
User selectable temperature scale ( ºC/ ºF) Language Selection Time/Date set Emissivity selection |
| Software |
Smart View full analysis and reporting software included |
| Power |
Battery: Internal rechargeable battery pack (included)
Battery life: 3 to 4 hours continuous use (assume 50% brightness of LCD)
Battery charge time using ac adapter/charger: 2 hours for full charge.
|
| AC operation/charging |
AC adapter/charger (110 V ac to 220 V ac, 50 Hz to 60 Hz). Charges battery while imager is operating. Universal ac mains adapters included. |
| Power saving |
Sleep mode activated after 5 minutes of inactivity, automatic power off after 30 minutes of inactivity. |
| Safety standards |
CE Directive: IEC/EN 61010-1 2nd Edition Pollution Degree 2 |
| Electromagnetic compatibility |
EMC directive: EN61326-1
C-Trick: IEC/EN 61326
US FCC: CFR 47, Part 15 Class A
|
| Vibration |
2 G, IEC 68-2-29 |
| Shock |
25 G,IEC 68-2-29 (1 m drop, 5 sides) |
| Dimensions(H x W x L) |
0.27 m x 0.13 m x 0.15 m (10.5 in x 5 in x 6 in) |
| Weight |
1.2 kg (2.65 lb) |
| IP rating |
IP54 |
| Warranty |
Two-years |
| Calibration Cycle |
Two-years (assumes normal operation and normal aging) |
| Supported languages |
English, Italian, German, Spanish, French, Russian, Portuguese, Swedish, Turkish, Czech, Polish, Finnish, Simplified Chinese, Traditional Chinese, Korean, and Japanese |
- Roofing Surveys: Detect wet areas in roofing systems quickly and efficiently. Find wet portions of the roofing structure and repair or replace before the entire roof is damaged.
- Energy Audits: Perform infrared energy audits for residential and commercial applications. Increase the thermal efficiency of a home or building by scanning for thermal heat loss, air infiltration or exfiltration, or air delivery problems.
- Moisture/Restoration: Accurately detect moisture issues located behind exterior and interior walls, in ceilings or under carpet-covered floors.
- Mold Remediation: Control mold by finding unknown sources of moisture that would otherwise go undetected.
|