RM10C HYBRID RECORDER
 
RM10C is 100mm calibrated hybrid recorder in a 144x144 DIN front panel and short depth of 150mm case housing.The recorder has versatility of universal input and scale in wide ranges and flexibility of user-reconfigurable unique functions. RM10C offers 1, 2 continuous pen and 6 dot point models.
  • Features
  • Specification
  • Applications
  • Brochures/Documents

  • Short Case Depth and Light Weight
    Dimension: 144W 144H 150D(mm)~
    Weight: 1.5kg~
  • IP-65: Dust-Proof, Water-Proof
  • Highly Responsive and Multi-Functional
  • Universal Input and Range
  • RS-232C Provided as Standard
  • Without Transducer
    RM10C (pH)
    Sensor Input: Glass or Metal Electrode (pH/ORP)
  • UL, CSA, CE Approved
TITLE ITEM PEN RECORDER MULTIPOINT RECORDER pH RECORDER
Input Measuring Point 1, 2 6 1
lnput sampling 125ms 10s/6ch 200ms
Type of input Direct voltage: ±10mV, 0-20mV, 0-50mV, ±200mV, ±1V, ±10V, 0-5V Glass electrode (pH or ORP)
Direct current: 4-20mA (250Ω shunt resistance required) Temperature compensation
Thermocouple: K, T,J, E, B, S, R, C, N, PR40-20, PL 2, L, Au-Fe, U 350Ω, 500Ω, 1kΩ, 6.8kΩ, 10kΩ
RTD: Pt100, JPt100
Analog retransmission 4-20mA DC isolated, 550Ω max. (Option)
Performance Accuracy ±(0.2% of rdg + 3digits) max. for Digital indicator Linearity: ±0.03pH(±3mV) Repeatability: ±0.02pH(±1mV)
Noise reduction NMRR: 60dB min. (50/60Hz±0.1Hz)
CMRR: 140dB min. (50/60Hz±0.1 Hz) 100dB min. (50/60Hz±0.1 Hz)
lsolation resistance0.5kV DC 20MΩ min. between theeach terminal and grounding terminal0.5kV DC 1000MΩ min. between R and G terminal and grounding terminal
Dielectric strength 1.5kV AC for 1 minute between power terminal and grounding terminal
0.5kV AC for 1 minute between input terminal and grounding terminal
Vibration resistance 10 to 60Hz 1m/s2 max.
Shock resistance 2m/s2 max.
Alarm Nos.of relay outputs 3 outputs (Form A contacts: Built-in option) 6 outputs (Form A contacts: Built-in option) 2 Alarm outputs, 2 types(H,L) 1 Error output(Form A contacts: Built-in option)
Alarm output contact capacity 250V AC 3A max. .(resistance load), 30V DC 3A max. .(resistance load)
Communication Interface RS-232C (Standard), RS-485 (Option) RS-232C (Standard)
Power supply Rated power voltage 100-240VAC (50/60Hz)
Power consumption 30VA max.(100V AC) 25VA max.(100V AC) 20VA max.(100V AC)
Structure 3Mounting/Housing Panel mounting / Front panel: Dust-proof, Water-proof (lP-65)
Dimension 144(W)x144(H)x150(D)mm 144(W)x144(H)x174(D)mm
Weight 1.8kg max. 1.5kg max. 2.0kg max.
Operation condition Allowable conditions Temperature: 0-50°C,Humidity: 20-80%RH
Recording /Printing Performance Recording Disposable felt pen Wire dot 6 color ribbon Disposable felt pen
Printing Wire dot 1color ribbon Wire dot 1color ribbon
95% step response time 1.0s max. 1.0s max.
Dot print interval 10.0s/6ch max.
Chart paper Length: 16m,Width: 114mm,Width folded: 40mm
Chart speed User-selective from 41 speeds User-selective from 34 speeds
in range: 5-12000mm/hr. in range: 0-1500mm/hr in range: 5-12000mm/hr.
Recording/Printing Color Red, Green Purple, Red, Green, Blue, Brown, Black Red
Safety Standard and EMI Standard Electrical safety Emissions lEC1010-1,UL3101-1 installation category 2 and pollution degree2. UL3101-1 EN55011 Group1 Class A
Immunity EN50082-2

  • Furnace monitoring for steel and metal processing
  • Remote control monitoring & recording of pump station
  • Flow leakage detection and alarm generation
  • Batch production and quality analysis
  • Gas and effluent emission recorder
  • Sterilisation & ultraviolet Disinfection processes recorder
  • Milk pasteurisation & other HACCP applications.
  • Cold storage and transport of perishable goods with Data logger (mini-log)
  • Pure water and waste water quality (pH, conductivity etc.) monitoring & recorder
  • Tank level monitoring and remote inventory management over modem
  • Limit overshoot, pump failure and event alarm over GSM messaging
  • Oven temperature monitoring & recording for Electric Manufacturing
 
 

Agencies