Toshniwal Industries Pvt. Ltd.
 
 
Call today on
+ 91 145 2695171
 

Solutions

Contact

Industrial Area, Mahukupura,
AJMER - 305 002,
INDIA
info@tipl.com
+ 91-145-2695171 / 72 / 73

Tag Cloud

Search

Search Tagged Items
LT and LR

  • Features
  • Specifications
  • Applications
  • Brochures
  • Available for various temperature range and optical requirements.
  • The strong 105:1 distance-to-spot ratio
  • –30 to 1200°C (-20 to 2200°F) temperature range
  • Permits easy temperature measurements of elevated objects at great distances, such as electrical connectors in towers.
  • Variety of laser sighting: single, dual, and crossed laser models
  • Scope sighting models available

Model

LT

LR

LRSCL2

Temperature Range

±1% of reading or ±1ºC (±1.5ºF)
whichever is greater at 23ºC ±5ºC
(73ºF ±9ºF) ambient operating
temperature

Accuracy

±1% of reading or ±1ºC (±1.5ºF)
whichever is greater at 23ºC ±5ºC
(73ºF ±9ºF) ambient operating
temperature

Repeatability

±0.5% of reading or ±1ºC ( ± 1ºF), whichever is greater

Response Time (95%)

700 mSec

Spectral Response

8 to 14µm

Adjustable Emissivity*
(from 0.1 to 1.0 by 0.01)

Available

Ambient Operating Temperature

0 to 50ºC (32 to 120ºF)

Relative Humidity

10 to 90%, noncondensing @ up to 30ºC (86ºF)

Storage Temperature

-20 to 50ºC (-4 to 120ºF) without batteries

Weight/Dimensions

Laser Models: 208 H x 257 L x 71 W mm / 794 g (8.2 H x 10.1 L x 2.8 W in / 1.75 lb)Scope Models: 244 H x 257 L x 71 W mm / 1000 g (9.6 H x 10.1 L x 2.8 W in / 2.21 lb)

Power

4 AA batteries or 6 to 9 V, 200 mA DC power supply

Battery Life (Alkaline)

21–25 hours

Laser

L2 models are IEC Class2/FDA Class II (<1mW), L3 models are FDA Class IIIa (<5mW)

Reflected Energy Compensation

Available

Distance to Spot (D:S)

75:1

120:1

105:1

MAX, MIN, DIF, AVG Temperatures

Available

Display Hold

7 Seconds

Backlit LCD

Available

Temperature Display

ºC or ºF (selectable), multifunction 4-digit backlit LCD

Display Resolution

1ºC or 1ºF

Locking Trigger

Available

Tripod Mounting

Available

Audible/Visible Hi/Lo Alarms

Available

Analog Output

1mV/ºC or 1mV/ºF

Digital Output

RS232, 9600 baud, output interval adjustable from 1 to 9999 seconds

100 Point Data Logging

Available

Options/ Accessories

Nylon carry case with shoulder strap • NIST Certification (Must be specified at time of order)Variable brightness filters (scope and G5 only) • 110V/60Hz or 220V/50Hz voltage adaptersPortable printer and cable • Computer, analog, and printer cables • DataTemp 2 software• Hard shell case

  • Utilities
  • Electrical Connectors
  • Plant Maintenance
  • Paper Production
  • Fire Safety
 
 

Agencies