EN6000B
Controller EN6000B1 is a generic control loop feedback mechanism widely used in industrial control system. This controller attempts to correct the error between a measured process variable and a desired set point by calculating and then outputting a corrective action that can adjust the process accordingly and rapidly, to keep the error minimal..
  • FEATURES
  • SPECIFICATIONS
  • APPLICATIONS
  • Brochure/Documents
  • Universal Input (T/C,RTD,Linear Input) and ranges.
  • 24V DC power supply for 2 wire transmitter.
  • High Accuracy.
  • Self Diagnosis Function:Input fails safe operation.
  • Multiple level keyboard locking function.
  • Adjustable PV offset.
  • Input /output programmable..
  • PID auto tunning or fuzzy control
  • Manual auto switching bump less.
  • Up to four alarms in 17 modes.
  • Remote set point.
  • Program controller 8 patternsX16 segment/1patternX129 segments.
  • Switching power supply: 85-260VAC,50 Hz or 24VDC.
  • Modular based output cards.
  • Heat cool,VMD,PID control output.
  • NPL traceable certificate.
Input Signal Temperature Thermocouple S,B,T,R,K,E,J,N,W Input drift:< 1micro V/ohm leads resistance
Sensor Break Protection Internal cold junction comp.:0-50 degC.
RTD Pt-100,Cu-100,Cu-50 Max. lead resistance: 100 ohm per lead.
Sensor break protection
Voltage 20-20mVDC,-100-100mVDC,0-100mVDC,0-500mVDC Max. lead resistance:100 ohm
0-100mVDC,0-5VDC,1-5VDC,0-10VDC
Input filter time:0-20 sec-Input impedance for current signals: 5 ohm; Input impedanc for other other signals:>600 kilo ohm.
Accuracy For linear Input 0.2% FS
For Temperature Input 0.2% FS+_2.0 deg C For B type of Thermocouple,may be more than 0.2%FS in the range of 0-400 deg C Cold junction compensation accuracy +_2 deg C
Control modes ON/OFF Control PID,P,PI or PD control Control cycle time:1-100 sec. Single action,reverse action head control or direct action cool control Double action, heat/cool control Positive/negative rotation control for position-proportion type of instrument
Output Signals Linear current 0-20mA,4-20mA (max. load : 500ohm) 0-10mA (max. load :1kilo ohm) Accuracy:+-0.3%FS
Relay 250VAC or 30VDC/1A for resistive load
SSR driver Von=13+-VDC(30mA max.),V off=0.1VDC
SCR trigger Zero-crossing trigger or phase shifting trigger output for 1-2 or 3 phase SCR 500A,upper power triac,or 2 inverse parallel SCR power modules.
Event input/output Event Input RSV/LSV selection,A/M switching,SV selection Passive contact,min holding time on or off should be 200ms
Event output PV alarm,A/M state Relay contact
Power output Isolated 24VDC/30mA power output
Retransmission PV,SV,OP1,OP2, or valve position selectable to be transmitted programmable
Communication RS232 (single instrument) RS485(max. 99 instruments)
Display PV 4-digit red LED Display resolution:0.001,0.01,0.1,1
SV 4-digit green LED Display cycle time:0.5sec
Light Bar 20 segments of red LED Display range:measuring range(-10%+10%)
Protection Automatic reset when operating abnormally Error code indication Multiple alarm type
Multilevel parameter safety protection Parameter are stored for an unlimited time
Operating conditions Power supply:100-240VAC(-15%+10%)50/60Hz or 24VDC(-15%+25%),6W max.
Temperature:0-50degC, Relative Humidity:5-85%RH(non condensing
Storage conditions Temperature:-25-70degC.
Relative Humidity:5-95% RH(non-condensing)
  • 1. Data Acquisition- It can capture high-quality measurements on many channels, at high data rates
  • 2. Integrated System- It use Channel Architecture technology to unify signal flow from sensors to software for large systems.
  • 3. Double output temperature control system.
  • 4. 3-phase SCR zero crossing/phase shifting control system.
  • 5. It is used for cascade control system.
  • 6. It is is also used in Position-proportion control system etc.
 
 