EN880 Process Recorder - Paperless

EN880 PROCESS RECORDER

GENERAL

EN880 is a new generation modular Paperless Process Recorder with highly enhanced innovative functionality. It has been developed by a highly qualified team with wife experience in electronic instrument development. The EN880 is a superior product with minimal maintenance requirement and low running cost when compared with traditional mechanical recorders. The design integrates the state of the art knowledge of computer, microelectronics, data storage, LCD and communication technologies to provide multiple display options, users friendly flexible setup procedure and comprehensive statistics analysis functions unparalleled by traditional recorders. The result is a very high performance-price ratio machine that has been well received by companies in multiple industrial sectors that include electronic power, petrochemical, metallurgical, light engineering and pharmaceutical companies.

CLASSIFICATION

The EN880 series models are categorized by basic type and special features with product specifications that encompass multiple features that can be transposed across several types. The basic models provide all of the primary functions of paperless recorders and are available in four, six, eight, twelve, sixteen, twenty four, thirty two & forty eight channel options. Models up 80 channels are also available on order. The LCD screen is colour, SVGA, TFT, 5.7 to 10.4 inch or 12.1 inch size. The alarm output feature is designed to trip a standard relay. The 4-Channel EN880 has 8 independent relay trips, the 6, 8 and the 12-channel EN880s have 12 independent relay trips and the 16-channel EN880 has 16 independent relay trips. The 24, 32 & 48 channel EN880 has 2 independent relay trips as standard and up to 16 relay trips as option. The relations between all alarm and channels can be defined through the setup procedure.

Customised EN880s can be built that add multiple user-specified special functions to the basic type functions. Customization widens the application field for process recorders and further improves their performance-price ratio.


ORDERING CODE

EN880XX/XX

1.      Special communication mode:

/CM      Remote MODEM communication mode with manual or automatic dialing;
/CS       User defined communication protocol and data format;
/CT       Communication via RS-232 port; 

2.      Special Input Signal:

/IF        Pulse or sign signal input-for measurement of frequency or rotation speed;
/IS        Switch input (active and passive); 

3.      Special Output Models:

        /OL       4-20ma PID output, PID parameter setup, automatic to manual switch, selection of negative or positive, output actions, Fixed
                    setpoint/programme control;
       /OS       SSR Drive PID output;
      /OV        Independent DC 12v or DC 24v outputs, supplying power to the user’s on site transmitter;

Others Points

Internal Data storage capacity up to  44MB, External removable memory (pen drive) of 128/256 on built in USB port; derived channels (up to 24); Special inputs signals & ranges; Higher Calibration accuracy; Special alarm Mode; Special flow compensation algorithm, 4-20Ma Retransmission output etc.

Other Custom functions can be offered by Envada to meet user specific requirement.

 

Models

Product model

EN880

    -00

EN880

     -01

EN880

-02

EN880

     -03

EN880

     -04

EN880

     -05

EN880

    -06

EN880 

    -07

Item description

No of Channels

4

6

8

12

16

24

32

48

Input Channels

Signals

(universal input)

Voltage: 0-10mV, 0-20mV, 0-5V, 1-5V, 0-10V, 1-10V (Optional: 0-100mv)

Current: 0-10mA, 4-20mA, 0-20mA (Optional :-1 to + 1mA, 0-100mA)

Resistance Thermometer (RTD):Pt100,BA1,Cu100,Cu53,Cu50(optional: PRT46 Cu 10)

Thermocouple (TC): S, R, B, K, N, E, J, T (Ref, Jun, Compensation & TC burnout – upscale response, built-in)

Transmitter Supply

24  VDC Power supply built in for 4-20mA signals from 2 wire Transmitter (Optional)

Filter Time

0-10 times

Measuring Range

Customised setup (Within overall range for RTD and thermocouple)

Channels Title/Signal’s unit

Customised setup

Isolation

Optical, 300 VAC

Screen Display

Screen

5.7” inch color TFT LCD (320x240 pixel) Optionally. 5.5” Inch color TFT LCD(320x240  pixel) or 10.4-inch /12.1 inch color TFT LCD

10.4 inch Color TFT LCD(640x480 pixels) Optionally. 12.1” Inch color TFT LCD(800x600  pixel)

Basic Display Mode

Bar graph Display, Digital Display, Vertical Display of graph (trend) 7 bar Graph, horizontal display of graph & bar Graph, cyclical and recall display(Optional: Polar Display); Alarm Status.

Channel for Display

No/ Name or Tag – Customised Setup

Color of the Bar & Chart

Customised Setup

N/A

Cyclical Screen Display Period

10-1800 sec

Cyclical Channel Display Period

5-60 sec

Upper and lower Display Limit

Customised Setup

Display Scale Factor

0.001 – 1000

Graph Shift Interval

1-399 sec

2-399 sec

Bar Chart Refresh time Interval

1-399 sec

Sleep Mode Time

1-499 sec (0 for Channel) – to Enhance LCD Life

Recall Display Mode

4 Kinds, from Internal memory; Only One Kind Displayed with a Cursor

Accuracy

Voltage 1 (0-10mV, 0-20mV)

*0.02mV

Voltage 2 (0-5V, 1-5V, 0-10V, 1-10V)

*0.15%

Current (0-10mA, 4-20mA, 0-20mA, 0-100mA)

*0.15%

Resistance Thermometer 1(pt 100, BA1)

*0.2%

Resistance Thermometer 2(Cu 100, Cu53, Cu50)

*0.9˚C

Thermocouple

S,R

*0.15%, *4˚C below 100˚C

B

*0.15% above 300˚C

K, N, E, J, T

*0.15%

 

Ref. Jun. Comp.

*1˚C  

Data  Record

Memory

16 MB built-in & 3.5 inch, 1.44M floppy disk;( Optional removable external memory)

Memory Status

- all memories are power failure protected, Lithium battery backup
Internal/ External Memory status (% filled) is displayed at the top of Recorder screen in the form of horizontal percentage bar/s & percentage figure.

 

Models

Product model

EN880

   -00

EN880

   -01

EN880

-02

EN880

    -03

EN880

    -04

EN880

    -05

EN880

    -06

EN880

  -  07

Item description

No of Channels

4

6

8

12

16

24

32

48

Data Record

Scan Time( for all channels) 

125 msec

200 msec

1 Sec

1.5 Sec

2 Sec

Fast Scan Time Up to 20 msec (Optional)

Recording Time Interval

0.1-1800 sec

0.2-1800 sec

Recording Period with std 16 MB Memory & 10 sec  rec Time Interval

>6800 Hours

>4500 Hours

>3400 Hours

>2500 Hours

>1700 Hours

>1280 Hours

>850 Hours

>640 Hours

Data download

Manually, Automatically

Alarm Output

Alarm Type

Upper And Lower Limit, Upper limit and Danger Lower limit and Danger

Warnings return difference

Customised Setup

Variation Rate Warning

Customised Setup

N/A

Alarm Limits

Customised Setup

Alarm Relays

8

12

16

2

Relay Distribution

Customised Setup-Each Channel Upper/Lower or Common for all Channels Configurable on any Relay

Capacity of Contact

2A/240 VAC, 50 Hz (Optionally: 55 VDC , 5 Amp)- Resistive Load;

Contact Type

COM & NO or COM & NC (Optional NC-COM-NO)

Stored Information in memory (Optional)

Alarm Occurrence and type (Most recent 40 events maximum), readable on screen.

Maths Functions/Flow

Keyboard Input Setup for each channels

Permits, addition ,subtraction, multiplication, division ,square, square root, programmable

Selection of flow Channel & totalizer

Available on all Channels

Temp and Pressure Compensation Channel

User Configurable

Communication

Mode (Standard)

RS 485(Optionally Modbus Protocol / RS 232 through RS 485 converter)

Baud Rate

2400,4800,9600,19200,38400(Optional)

2400,4800,9600,19200

Data Length

16 bit

Stop bit

1 bit

Time Synchronization

Will accept time Sync pulse from host PC (Optional)

Ethernet (Optional)

10 base t

Software

Data Management

Support multi drop networking (up to 64 Recorders) & real time data monitoring for display (recall), software analysis, statistic, printing & export (in MS word/Excel format) of data download from EN880 through RS485/ floppy disk.

Power Supply

Rated Power Voltage

85-260V AC

Rated Power Frequency

50Hz +/- 3Hz

Instrument Power Consumption

<26 W

<30 W

Environment

Case

Metallic

Protection Class

Water/dust protected (front panel only)

Temperature

0-50˚C

Humidity

<80%, no condensation

Installation

Installation Mode

Flush Panel Mounting

Cutout Size

138 x 138 mm

200 x 200 mm

Font Bezel Size

164 x 164 mm (with 5.7” LCD)

144 x 144 mm (with 5.5” LCD Option)

288 x 288 mm

 EN880 PROCESS RECORDER

Features & Functions

Multiple Display Modes
The EN880 has 6 basic display modes: bar chart display (Figure 1), horizontal display of bar chart and vertical display of graph (Figure 2), vertical display of bar chart and horizontal display of graph (Figure 3), digital display (Figure 4), cyclical display and recall display. The 16-channel EN880 also has a polar (circular) display (Figure 5).

The display modes for each channel can be set up and combined by users allowing the display to be Customised to their requirements. The basic display functions incorporate many real time ergonomically designed functions including date, time, channel description (8 alpha-numeric characters for each channel), physical units being measured for each channel (more than 40 standard units are stored in memory for user selection. Additional units can be added by users), multi-level alarm limit bars, signal scale and amplification level, alarm state, time coordination on the colors for graphs, bar charts and background based on individual requirements. The screen refresh time interval, recording time interval and the cyclical screen shift time interval can also be selected by the user.

 

 

 

 

 

 

SIMPLE OPERATION

The EN880 incorporates 6 push button keys that provide all of the necessary functionality. A single key press is all that is needed to switch between display modes and to page scroll between displays under standard operating conditions (non-set up state). The setup procedure is accomplished through user friendly popup selection windows that are simple to use.

POWERFUL SETUP FUNCTION
The EN880’s operating modes and functions, together with the modification of specific parameters are selected through the setup functions. The simplicity of use of the setup function in defining the wide input range and powerful functions are the main feature in the usability of the EN880. 

All the setup procedure are facilities by pop-up menus that incorporate on-line help prompts, making it unnecessary to provide special training for users. Every time the user completes a setup, its contents are permanently saved and will not be lost even if there is a long power-off.

Password protection of the setup system is provided to prevent access by unauthorized users and to protect important parameters. The setup of minor user preference does not need password protection. The setup menu structure is shown in figure 6

 

 

Flow Measurement

EN880 has a powerful flow measurement capability that can  display and record both the instantaneous flow and the cumulative flow for each channel. The flow parameter setup window is shown in figure 7. the user can set the relationship between the indicated value and signal. Built in options include linearity, extraction of square root, differential pressure extraction, differential pressure linearity, linear compensation and inverse ratio. The user can also set the channels for flow input. Flow medium, totalizer required or not, initial value for Totalizer, reset choice and Timed reset. Flow signal temperature and pressure compensation can be set the using relative parameters in “Temperature and pressure compensation setup” window as shown on Figure 8.

IN-BUILT FLOPPY DRIVE 

A3.5” floppy drive is provided for the following functions:

·          Data Download to Floppy Disk

·          Upload Channel Parameter File

·          Download Channel Parameter File

·          Software Upgrade

Data Recall
The recall function accesses the historic data recorded on the EN880 electronic disk and display then in continues graph mode, as shown in Figure9. For the appropriate user-designated channels, the shortcut keys select the recall functions such as forward display, backward, rapid display, slow display and display pause etc. the cursor line can be used to mark and display the accurate record data value and record time for any point on the recall curve. This provides a simple, convenient and effective method for observation and analysis of historic data.

Data Statistics
The user can access the data statistic function to recover the data statistic for each channel in the designated time period. Information available includes the maximum and minimum values in the time period, the time they occurred, the average value in this period, times when the alarms were triggered and accumulated alarm time as Shown in Figure 10.

Alarms
The EN880 has been designed with a multiple alarm function that trigger contact relays. The user can select which of the different alarm types will be activated. Alarm types include very high, high, low & vary low limits with methods that encompass return difference alarm, variance rate alarm, alarm time and contact state. All alarm outputs can be independently specified for each channel through the setup procedures. It is permissible for several channel alarms to trigger the same output alarm relay.

 

Communication/Networking
EN880 has two communication modes. Multiple EN880s can be using the LAN mode to a data control personal computer. Alternatively, remote communication mode can be achieved using standard telephone line and the built in MODEM. Envada can either provided the user with the standard communication software which can be operated on PC, or modify the EN880 communication software to map on to the user’s communication protocol so as to be connected using an existing LAN. 

Data Management Software
The Envada data management software runs in the Windows-9x/Me/NT/200/XP environments as shown in figure 11. This powerful software can be used for display, analysis, statistic and printing of data download from EN880 through the RS485/Ethernet digital output or the floppy disk.

 

 

 

 

 

 


 